SolidificationPaper
PDAS across a single-crystal casting – why dendrites are not finest next to the chill ring
In an industrial Bridgman furnace the side of the rod next to the chill ring, where the axial gradient is highest, had a coarser PDAS than the centre. The tilt of the liquidus isotherm matters, not just G and v.